| Controller Options Provide Capability for Specialized Testing |
|
| Option Code |
Description |
| -MODE |
Allows certain L-Series models to be IEEE-programmed or switch configured for single-phase or three phase output. |
| -MT |
Primarily for military applications, where CIIL and full confidence test is required. Not available on 751L. |
| -RPV |
Allows amplitude of any L-Series unit, when using a manual oscillator, to be programmed with an external 0 - 10 VDC input. |
| -SQW |
Allows square wave capability with programmable controller. Not available on 2750L-1, 4500L-1, 6000L or any multi-box system. |
| -704 |
MIL-STD-704 test. These test routines are embedded in the -P and -PT controller along with the standard APE language. |
| -160 |
RTCA/DO-160 test. These test routines are embedded in the -PT controller along with the standard APE language.
(not available on -P controller) |
|
 |
|
 |
| L-Series Amplifier Options Provide Additional Flexibility |
|
| One of the following may be specified |
| Option Code |
Description |
| -HV |
High voltage. Changes output transformer to 156 V/ 312 V, L-N. |
| -EHV |
Extra high voltage. Changes output transformer to 200 V/ 400 V, L-N (45 Hz to 1000 Hz frequencies only). |
| -LV |
Low voltage. Changes output transformer to 67.5 V/ 135 V, L-N. Especially useful when 115 V, L-L is
required |
| Any of the following may be specified |
| -AX |
Provides separate isolated 26 VAC regulated and 5 VAC unregulated outputs. The 26 V is normally used for servo-synchro excitation, and the 5 V for lamp power. Available on Models 2750L, 4500L, 1503L only.
26 Volt - Accuracy: ±2%. Current Capacity: 3 ARMS. Frequency: 360/440 Hz. Regulation: ±0.05%
5 Volt - Accuracy: ±5%. Current Capacity: 5 ARMS. |
| -UP |
Allows any system configured from Model 4500L and up to accept 3-phase L-L voltage from 342 V to 456 V,
L-L. |
| -LKM |
Clock/Lock Master Unit. Installs necessary hardware to adapt to one slave unit |
| -LKS |
Clock/Lock Slave Unit. Installs necessary hardware to accept Clock/Lock inputs from LKM unit. Only one slave unit may be driven from a master unit |
| 210960 |
Rack slides. Required for mounting in 19” (483 mm)
instrument rack. |
|
 |
|
 |
|
 |
|
 |