AMETEK Programmable Power
AC Power Sources
Elgar and California Instruments Power Products
DC Products Bench Products AC Products Modular AC/DC Electronic Loads Custom Solutions
Overview Features Specifications Technical Diagrams Downloads Get a Quote
California Instruments i/iX Series II : Specifications
Operating Modes
Model iX Series II i Series II
Modes AC, DC or AC+DC AC or DC
AC Mode Output
Frequency Range: 16.00-1000 Hz (Note: Voltage on 300 V range derates from 300 Vrms max at 500 Hz to 150 Vrms max at 1000 Hz; See V-F rating chart. below)
Total Power 3001i/iX: 3000 VA, 5001i/iX: 5000 VA, 9003i/iX: 3000 VA 3ø, with mode iX: 9000 VA 1ø, 10001i/iX: 10000 VA, 15001i/iX: 15000
VA, 15003i/iX: 5000 VA/ø 3ø, with mode iX: 15000 VA/ø 1ø
Load Power Factor 0 to unity at full output VA
AC Mode Voltage
Voltage Ranges Range VLow VHigh
AC 0-150 V 0-300 V
AC+DC 0-150 V 0-300 V
Load Regulation
(with ALC on)
< 0.2%
Load Regulation
(with ALC off)
< 0.5% DC to 100 Hz,
< 0.6% 100 Hz to 500 Hz in high voltage range,
< 2.2% 100 Hz to 500 Hz in low voltage range,
< 3% 500 Hz to 1000 Hz
Line Regulation < 0.1% for 10% line change
Output Noise
(20 kHz to 1 MHz)
< 250 mVrms typ., < 500 mVrms max.
Harmonic Distortion (Linear) < 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load)
DC Offset < 20 mV External Amplitude Modulation: Depth: 0 - 10 %, Frequency: DC - 2 KHz
Isolation Voltage 300 Vrms output to chassis
New Expanded AC Product Line Featuring California Instruments
   
AC Electronic Loads
AC Modular Supply
Discontinued Products
Product Support
Contact Sales
   
Service Agreement for all California Instruments AC except MX & FCS
AC Mode Current
Steady State AC Current
Model 3001i
/iX
5001i
/iX
9003i
/iX 3ø
10001i
/iX
15001i
/iX
15003i
/iX 3ø
300 V range 11.1 18.5 11.1 /ø 37.0 55.5 18.5 /ø
150 V range 22.2 37.0 22.2 /ø 74.0 111.0 37.0 /ø
Note: Constant power mode provides increased current at reduced voltage (See chart below)
Peak Repetitive AC Current
Model 3001i
/iX
5001i
/iX
9003i/iX 3ø 10001i
/iX
15001i
/iX
15003i
/iX 3ø
High range 96.0 96.0 96.0 /ø 192.0 288.0 96.0 /ø
Low
range
110.0 110.0 110.0 /ø 220.0 330.0 110.0 /ø
Programming Accuracy Voltage (rms): ± 0.2 of range, 16 to 1000 Hz, Frequency: ± 0.01 % of programmed value, Current Limit: ± 0.5 % of programmed value, Phase: < 1.5° with balanced load at 50/60 Hz
Programming Resolution Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819.1 Hz, 1 Hz from 820-1000 Hz, Current Limit: 0.1 A, Phase, 0.1°
Output Relay Push-button controlled or bus controlled output relay
Output Impedance
(iX Only)
Programmable Z on 3001iX, 5001iX, 9003iX and 15003iX (3ø mode only) for 50 Hz fundamental
Resistive Range: 17 - 1000 mOhm,resolution: 4 mOhm accuracy, 2 % FS
Inductive Range: 230 - 1000 μH, resolution: 4 μH, accuracy: 2 % FS
Constant Power AC Mode - Available Max. AC Current

V-F Rating Chart - 300V Range

Measurements - Standard (AC Measurements)
Parameter Frequency RMS Voltage RMS Current Peak Current Crest Factor Real Power Apparent Pwr Pwr Factor DC Voltage DC Current Power
Range 16-500 Hz 0-300 V 0-40 A 0-120 A 0.00-6.00 0-6 kW 0-6 kVA 0.00-1.00 0-300 V 0-40 A 0-6 kW
Accuracy* (±)
0.01% +
0.01 Hz
< 100 Hz 0.5 V + 0.02% 0.5 A + 0.02% 0.5 A + 0.02% 0.05 10 W + 0.1% 10 VA + 0.1% 0.01 150 mV 70 mA 15 W
100 - 500 Hz 0.1 V + 0.02% 0.1 A + 0.02% 0.1 A + 0.02% 0.05 20 W + 0.1% 20 VA + 0.1% 0.02 150 mV 70 mA 15 W
Resolution* 0.01 Hz 10 mV 1 mA 1 mA 0.01 1 W 1 VA 0.01 10 mV 1 mA 1 W
* Measurement system bandwidth = DC to 48 kHz. Accuracy specifications are valid above 100 counts. Current and Power Accuracy specifications are times two for 10001i/iX /30003i/iX and times three for 15001i/iX and 9003i/iX and 15003i/iX with MODE-iX option when in single phase mode. For 10001i/iX, 15001i/iX and 30003i/ iX, resolution decreases by factor of 10, ranges for current and power increases by factor of three. PF accuracy applies for PF > 0.5 and VA > 50% of range.
Measurements - Harmonics
Parameter Frequency Fundamental Harmonics Phase Voltage Current
Range 16.00-500.0 Hz / 32.00 Hz - 48.00 kHz 0.0 - 360.0° Fundamental Harmonics 2 - 50 Fundamental Harmonics 2 - 50
Accuracy* (±) 0.01% + 0.01 Hz 2° typ. 250 mV 0.1% + 250 mV+0.1% /1 kHz 50 mA/0.1% + 50 mA +0.1% /1 kHz
Resolution 0.01 Hz 0.5° 10 mV / 10 mV 10 mA / 10 mA
* Accuracy specifications are valid above 100 counts. Accuracy specifications are times three for three phase mode. Harmonics frequency range in three phase mode is 32 Hz - 16 kHz. Resolution decreases by factor of 10 for 9003iX and 15003iX with Mode-iX option in 1 phase mode and for 10001iX, 15001iX and 30003i/iX.
DC Mode Output
Power (Max at full scale of DC Voltage Range) 3001i/iX: 2100 W, 5001i/iX: 3500 W, 9003i/iX: 2100 W/ø 3ø, 6300 W/ø 1ø, 10001i/iX: 7000 W, 15001i/iX: 10500 W, 15003i/iX: 3500
W/ø 3ø, 10500 W/ø 1ø
Voltage Ranges Range: Low: 200 Vdc, High: 400 Vdc
Line Regulation < 0.1% FS or 10% line change
Output Noise < 250 mV rms typ., < 500 mV rms max., (20 kHz to 1 MHz)
Max DC Current (Maximum current at 65% of V Range):
Model 3001i
/iX
5001i
/iX
9003i
/iX
9003i
/iX 3ø
10001i
/iX
15001i
/iX
15003i
/iX 3ø
400V range 7.8 13 23.4 7.8 26 39 13
200V range 15.6 26 46.8 15.6 52 78 26
Current Limit Programmable from 0 A to maximum current for selected range
AC+DC Mode Output
Output Power (iX only) Full AC Power if DC component is less than 20% of full scale voltage, Full DC power if DC component is above 20%
Storage
Non Volatile Mem. storage 16 instrument setups, 200 user defined waveforms
Waveforms
Waveform Types i Series II: Sine, iX Series II: Sine, Square, Clipped sine, User defined
User defined waveform
storage
Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200 (One group can be active at a time)
System Interface
Inputs Remote shutdown, External Sync, Clock/Lock (option)
Outputs Function Strobe, Clock/Lock (option)
Protection
Over Load Constant Current or Constant Voltage mode
Over Temperature Automatic shutdown
Remote Control
IEEE-488 Interface IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax
RS232C Interface 9 pin D-shell connector, Handshake: CTS, RTS, Data bits: 7,8, Stop bits: 1, 2, Baud rate: 9600, 19200, 38400, 57600, 115200, IEEE-488.2 SCPI Syntax (Supplied with RS232C cable)
DC Mode Output
Voltage 3001 and 9003: 208-240 ± 10% Vac, (L-N, 1ø), All other models: Standard: 208-240 ± 10% Vac, (L-L, 3ø), Option -400: 400-480 ± 10% Vac, (L-L, 3ø) (Input range must be specified when ordering)
Max DC Current (Maximum current at 65% of V Range):
Model 3001i/iX 5001i/iX 9003i/iX 10001i/iX 15001i/iX 15003i/iX
187-264V 25 A 23 A 75 A 46 A 69 A 69 A
360-528V N/A 12 A N/A 24 A 36 A 36 A
Inrush Current per chassis < 100 Apk for 100 μs at 208-240 V, < 50 Apk for 100 μs at 400-480 V
Line Frequency 50-60 Hz ± 10 %
Efficiency 75% typical
Power Factor 0.6 typical
AC Service
Regulatory IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements
RFI Suppression CISPR 11, Group1 , Class A
Rear Panel Connectors AC Input & Output terminal block with cover, IEEE-488 (GPIB) connector (rear panel), 9 pin D-Shell RS232C connector*, Remote voltage sense terminal block, System Interface Connector, *RS232 DB9 to DB9 cable supplied
Physical Dimensions
Dimensions Height: 7” (178 mm), Width: 19” (483 mm), Depth: 24” (610 mm)
(depth includes rear panel connectors)
Weight per 5001i/iX Chassis: Net: 61 lbs / 28 Kg, Shipping: 115 lbs / 52 Kg
Vibration and Shock Designed to meet NSTA project 1A transportation levels
Air Intake/Exhaust Forced air cooling, side air intake, rear exhaust.
Operating Humidity 0 to 95 % RAH, non condensing.
Temperature Operating: 0 to 40° C, Storage: -20 to +85° C