| Model |
iX Series II |
i Series II |
| Modes |
AC, DC or AC+DC |
AC or DC |
|
 |
|
 |
|
| Frequency |
Range: 16.00-1000 Hz (Note: Voltage on 300 V range derates from 300 Vrms max at 500 Hz to 150 Vrms max at 1000 Hz; See V-F rating chart. below) |
| Total Power |
3001i/iX: 3000 VA, 5001i/iX: 5000 VA, 9003i/iX: 3000 VA 3ø, with mode iX: 9000 VA 1ø, 10001i/iX: 10000 VA, 15001i/iX: 15000
VA, 15003i/iX: 5000 VA/ø 3ø, with mode iX: 15000 VA/ø 1ø |
| Load Power Factor |
0 to unity at full output VA |
|
 |
|
 |
|
| Voltage Ranges |
Range |
VLow |
VHigh |
| AC |
0-150 V |
0-300 V |
| AC+DC |
0-150 V |
0-300 V |
 |
Load Regulation
(with ALC on) |
< 0.2% |
Load Regulation
(with ALC off) |
< 0.5% DC to 100 Hz,
< 0.6% 100 Hz to 500 Hz in high voltage range,
< 2.2% 100 Hz to 500 Hz in low voltage range, < 3% 500 Hz to 1000 Hz |
| Line Regulation |
< 0.1% for 10% line change |
Output Noise
(20 kHz to 1 MHz) |
< 250 mVrms typ., < 500 mVrms max. |
| Harmonic Distortion (Linear) |
< 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load) |
| DC Offset |
< 20 mV External Amplitude Modulation: Depth: 0 - 10 %, Frequency: DC - 2 KHz |
| Isolation Voltage |
300 Vrms output to chassis |
|
 |
|
 |
|
 |
|
 |
|
|
|
| Model |
3001i
/iX |
5001i
/iX |
9003i
/iX 3ø |
10001i
/iX |
15001i
/iX |
15003i
/iX 3ø |
| 300 V range |
11.1 |
18.5 |
11.1 /ø |
37.0 |
55.5 |
18.5 /ø |
| 150 V range |
22.2 |
37.0 |
22.2 /ø |
74.0 |
111.0 |
37.0 /ø |
|
| Note: Constant power mode provides increased current at reduced voltage (See chart below) |
|
| Peak Repetitive AC Current |
|
| Model |
3001i
/iX |
5001i
/iX |
9003i/iX 3ø |
10001i
/iX |
15001i
/iX |
15003i
/iX 3ø |
| High range |
96.0 |
96.0 |
96.0 /ø |
192.0 |
288.0 |
96.0 /ø |
Low
range |
110.0 |
110.0 |
110.0 /ø |
220.0 |
330.0 |
110.0 /ø |
|
| Programming Accuracy |
Voltage (rms): ± 0.2 of range, 16 to 1000 Hz, Frequency: ± 0.01 % of programmed value, Current Limit: ± 0.5 % of programmed
value, Phase: < 1.5° with balanced load at 50/60 Hz |
| Programming Resolution |
Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819.1 Hz, 1 Hz from 820-1000 Hz, Current Limit: 0.1 A, Phase, 0.1° |
| Output Relay |
Push-button controlled or bus controlled output relay |
Output Impedance
(iX Only) |
Programmable Z on 3001iX, 5001iX, 9003iX and 15003iX (3ø mode only) for 50 Hz fundamental |
| Resistive |
Range: 17 - 1000 mOhm,resolution: 4 mOhm accuracy, 2 % FS |
| Inductive |
Range: 230 - 1000 μH, resolution: 4 μH, accuracy: 2 % FS |
|
|
 |
|
 |


| Measurements - Standard
(AC Measurements) |
|
| Parameter |
Frequency |
RMS Voltage |
RMS Current |
Peak Current |
Crest Factor |
Real Power |
Apparent Pwr |
Pwr Factor |
DC Voltage |
DC Current |
Power |
| Range |
16-500 Hz |
0-300 V |
0-40 A |
0-120 A |
0.00-6.00 |
0-6 kW |
0-6 kVA |
0.00-1.00 |
0-300 V |
0-40 A |
0-6 kW |
Accuracy* (±)
0.01% +
0.01 Hz |
< 100 Hz |
0.5 V + 0.02% |
0.5 A + 0.02% |
0.5 A + 0.02% |
0.05 |
10 W + 0.1% |
10 VA + 0.1% |
0.01 |
150 mV |
70 mA |
15 W |
| 100 - 500 Hz |
0.1 V + 0.02% |
0.1 A + 0.02% |
0.1 A + 0.02% |
0.05 |
20 W + 0.1% |
20 VA + 0.1% |
0.02 |
150 mV |
70 mA |
15 W |
| Resolution* |
0.01 Hz |
10 mV |
1 mA |
1 mA |
0.01 |
1 W |
1 VA |
0.01 |
10 mV |
1 mA |
1 W |
| * Measurement system bandwidth = DC to 48 kHz. Accuracy specifications are valid above 100 counts. Current and Power Accuracy specifications are times two for
10001i/iX /30003i/iX and times three for 15001i/iX and 9003i/iX and 15003i/iX with MODE-iX option when in single phase mode. For 10001i/iX, 15001i/iX and 30003i/
iX, resolution decreases by factor of 10, ranges for current and power increases by factor of three. PF accuracy applies for PF > 0.5 and VA > 50% of range. |
|
 |
|
 |
|
| Parameter |
Frequency Fundamental Harmonics |
Phase |
Voltage |
Current |
| Range |
16.00-500.0 Hz / 32.00 Hz - 48.00 kHz |
0.0 - 360.0° |
Fundamental Harmonics 2 - 50 |
Fundamental Harmonics 2 - 50 |
| Accuracy* (±) |
0.01% + 0.01 Hz |
2° typ. |
250 mV 0.1% + 250 mV+0.1% /1 kHz |
50 mA/0.1% + 50 mA +0.1% /1 kHz |
| Resolution |
0.01 Hz |
0.5° |
10 mV / 10 mV |
10 mA / 10 mA |
| * Accuracy specifications are valid above 100 counts. Accuracy specifications are times three for three phase mode. Harmonics frequency range in three phase mode is
32 Hz - 16 kHz. Resolution decreases by factor of 10 for 9003iX and 15003iX with Mode-iX option in 1 phase mode and for 10001iX, 15001iX and 30003i/iX. |
|
 |
|
 |
|
| Power (Max at full scale of
DC Voltage Range) |
3001i/iX: 2100 W, 5001i/iX: 3500 W, 9003i/iX: 2100 W/ø 3ø, 6300 W/ø 1ø, 10001i/iX: 7000 W, 15001i/iX: 10500 W, 15003i/iX: 3500
W/ø 3ø, 10500 W/ø 1ø |
| Voltage Ranges |
Range: Low: 200 Vdc, High: 400 Vdc |
| Line Regulation |
< 0.1% FS or 10% line change |
| Output Noise |
< 250 mV rms typ., < 500 mV rms max., (20 kHz to 1 MHz) |
| Max DC Current (Maximum
current at 65% of V Range): |
|
| Model |
3001i
/iX |
5001i
/iX |
9003i
/iX |
9003i
/iX 3ø |
10001i
/iX |
15001i
/iX |
15003i
/iX 3ø |
| 400V range |
7.8 |
13 |
23.4 |
7.8 |
26 |
39 |
13 |
| 200V range |
15.6 |
26 |
46.8 |
15.6 |
52 |
78 |
26 |
|
|
| Current Limit |
Programmable from 0 A to maximum current for selected range |
|
 |
|
 |
|
| Output Power (iX only) |
Full AC Power if DC component is less than 20% of full scale voltage, Full DC power if DC component is above 20% |
|
 |
|
 |
|
| Non Volatile Mem. storage |
16 instrument setups, 200 user defined waveforms |
|
 |
|
 |
|
| Waveform Types |
i Series II: Sine, iX Series II: Sine, Square, Clipped sine, User defined |
User defined waveform
storage |
Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200 (One group can be active at a time) |
|
 |
|
 |
|
| Inputs |
Remote shutdown, External Sync, Clock/Lock (option) |
| Outputs |
Function Strobe, Clock/Lock (option) |
|
 |
|
 |
|
| Over Load |
Constant Current or Constant Voltage mode |
| Over Temperature |
Automatic shutdown |
|
 |
|
 |
|
| IEEE-488 Interface |
IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
| RS232C Interface |
9 pin D-shell connector, Handshake: CTS, RTS, Data bits: 7,8, Stop bits: 1, 2, Baud rate: 9600, 19200, 38400, 57600, 115200, IEEE-488.2
SCPI Syntax (Supplied with RS232C cable) |
|
 |
|
 |
|
| Voltage |
3001 and 9003: 208-240 ± 10% Vac, (L-N, 1ø), All other models: Standard: 208-240 ± 10% Vac, (L-L, 3ø), Option -400: 400-480 ± 10%
Vac, (L-L, 3ø) (Input range must be specified when ordering) |
| Max DC Current (Maximum
current at 65% of V Range): |
|
| Model |
3001i/iX |
5001i/iX |
9003i/iX |
10001i/iX |
15001i/iX |
15003i/iX |
| 187-264V |
25 A |
23 A |
75 A |
46 A |
69 A |
69 A |
| 360-528V |
N/A |
12 A |
N/A |
24 A |
36 A |
36 A |
|
| Inrush Current per chassis |
< 100 Apk for 100 μs at 208-240 V, < 50 Apk for 100 μs at 400-480 V |
| Line Frequency |
50-60 Hz ± 10 % |
| Efficiency |
75% typical |
| Power Factor |
0.6 typical |
|
 |
|
 |
|
| Regulatory |
IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements |
| RFI Suppression |
CISPR 11, Group1 , Class A |
| Rear Panel Connectors |
AC Input & Output terminal block with cover, IEEE-488 (GPIB) connector (rear panel), 9 pin D-Shell RS232C connector*, Remote voltage
sense terminal block, System Interface Connector, *RS232 DB9 to DB9 cable supplied |
|
 |
|
 |
|
| Dimensions |
Height: 7” (178 mm), Width: 19” (483 mm), Depth: 24” (610 mm)
(depth includes rear panel connectors) |
| Weight |
per 5001i/iX Chassis: Net: 61 lbs / 28 Kg, Shipping: 115 lbs / 52 Kg |
| Vibration and Shock |
Designed to meet NSTA project 1A transportation levels |
| Air Intake/Exhaust |
Forced air cooling, side air intake, rear exhaust. |
| Operating Humidity |
0 to 95 % RAH, non condensing. |
| Temperature |
Operating: 0 to 40° C, Storage: -20 to +85° C |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
 |
|